California's Chromium-6 Limit Now Applies to Its Largest Water Systems

Since October 1, 2026, California water systems with 10,000+ connections must meet a 10 ppb limit for hexavalent chromium. What it means for your tap water.

Short answer: California’s limit for hexavalent chromium (chromium-6) in drinking water is 10 parts per billion (ppb). The rule took effect on October 1, 2024, with deadlines phased by system size, and the first one arrived on October 1, 2026: water systems with 10,000 or more service connections must now comply. Systems with 1,000 to 9,999 connections follow on October 1, 2027, and smaller ones on October 1, 2028. If you get water from a California utility, its yearly water quality report already lists any chromium-6 detections. Private wells aren’t covered.

What changed on October 1?

The State Water Resources Control Board adopted the limit, a maximum contaminant level (MCL) of 0.010 mg/L, in 2024. The regulation (22 CCR 64432) gives each system a compliance date based on its size on October 1, 2024:

System size (service connections) Must comply by
10,000 or more October 1, 2026
1,000 to 9,999 October 1, 2027
Fewer than 1,000 October 1, 2028

The board’s FAQ says smaller systems get more time because they have fewer resources and fewer households to spread costs over, and because larger systems going first lets treatment be refined before the smallest systems have to pay for it.

Compliance is judged like other inorganic chemicals, on a running annual average of quarterly samples. For a large system, the first full average will cover the last quarter of 2026 through the third quarter of 2027. But the FAQ is clear that “if any one sample would cause the annual average to exceed the MCL, the system would immediately be in violation.”

Before its date, a system with a source over 10 ppb isn’t in violation, but it isn’t off the hook either: it must send the state a compliance plan within 90 days, give customers a Tier 2 public notice, and say so in its yearly water quality report.

How strict is 10 ppb?

California’s public health goal for hexavalent chromium, set in 2011, is 0.02 ppb. The board is required to set the legal limit as close to that goal as is technologically and economically feasible, and says a limit at the goal wasn’t: only a few labs can measure as low as the goal, and treatment hasn’t been studied below about 1 ppb. At 10 ppb, the board puts the remaining risk at a one-in-two-thousand chance of developing cancer over 70 years of drinking the water.

There’s no separate federal limit for hexavalent chromium. Federal rules (40 CFR 141.62) cap total chromium at 0.1 mg/L (100 ppb), and California keeps its own stricter total chromium limit of 50 ppb alongside the new one.

Is chromium-6 in your water?

Chromium is odorless and tasteless, so you can’t tell by drinking. The board says much of it occurs naturally from eroding chromium deposits, and some comes from industrial pollution. According to the board, long-term exposure to water contaminated with it may cause liver toxicity, gastrointestinal tumors and liver cancer.

On the board’s chromium-6 page, monitoring from 2012 to February 2022 detected it more than once in 7,780 water sources. In 88% of them the average was between 1 and 5 ppb; 327 averaged more than 10 ppb. The board cautions that these are source results, not necessarily the water customers drink, since sources may be blended, treated or unused. Its FAQ names San Bernardino, Los Angeles and Fresno as the counties with the most sources currently over the limit.

To check your own water:

  • City water: look for “Chromium (hexavalent)” in your utility’s yearly report. The board requires every detection to be listed, even before a system’s compliance date. Our guide to reading your water quality report explains the table. Many reports are also on the state’s Drinking Water Watch site.
  • A private well: the rule doesn’t apply, so testing is up to you. The board points well owners to labs accredited by its Environmental Laboratory Accreditation Program (ELAP) and to its Groundwater Ambient Monitoring and Assessment (GAMA) program. See our well water testing guide for how to arrange a test.

Should you filter it?

Only if your water actually has it at a level that concerns you. The board lists ion exchange, reduction-coagulation-filtration and reverse osmosis as the best available treatment for utilities. At home, it says point-of-use devices, often pitchers, are more common than whole-house systems for chromium-6, that the state keeps a list of certified devices, and that reductions vary by device. It doesn’t recommend bottled water as a way around it, because bottled water isn’t tested for hexavalent chromium.

If you shop for a filter, look for hexavalent chromium by name on the certifier’s listing for your exact model. In WQA’s directory, for example, the claim to search for is “Hexavalent Chromium”. California’s registered device database can be searched by contaminant too. Our guide to checking a filter’s certification walks through the steps.

What happens next

Mid-size systems (1,000 to 9,999 connections) must comply by October 1, 2027, and the smallest by October 1, 2028. This rule applies only in California; federal rules still regulate only total chromium.

Sources

  1. Hexavalent Chromium MCL (Chromium-6 Drinking Water) (Clinical guideline, California State Water Resources Control Board, 2026)
  2. Maximum Contaminant Level (MCL) for Hexavalent Chromium: Frequently Asked Questions (updated November 2024) (Clinical guideline, California State Water Resources Control Board, 2024)
  3. Cal. Code Regs. tit. 22, § 64432, Monitoring and Compliance, Inorganic Chemicals (Clinical guideline, Legal Information Institute, Cornell Law School, 2026)
  4. 40 CFR 141.62, Maximum contaminant levels for inorganic contaminants (Clinical guideline, Legal Information Institute, Cornell Law School, 2026)
  5. Residential Water Treatment Devices (Clinical guideline, California State Water Resources Control Board, 2026)
  6. Find WQA Certified Products (Source, Water Quality Association, 2026)